½Å¿µ°ø¾÷(ÁÖ)ÀÇ ¾Ë¶÷¹ëºê´Â ½À½Ä ½ºÇÁ¸µÅ¬·¯ ½Ã½ºÅÛ¿¡ ÇʼöÀûÀ¸·Î »ç¿ëµÇ´Â ¹ëºêÀ̸ç, È­Àç½Ã¿¡ ¹è°ü³» ¹°ÀÇ È帧À» ÀÚµ¿°¨Áö
½ÃÅ°°í À̸¦ ÀÌ¿ëÇÏ¿© ¼ö½Å±â¿¡ Çش籸¿ª¿¡ °æº¸¸¦ ¿ï¸®°Ô ÇÕ´Ï´Ù.
¾Ë¶÷¹ëºê´Â ÀÚüÀûÀ¸·Î ³»¾Ð½ÃÇè, ±â´É½ÃÇè°ú ¿Ü°ü°Ë»çµîÀ» öÀúÇÏ°Ô ¸¶Ä£ ÈÄ ±¹°¡°ËÁ¤À» ¹Þ¾Æ¼­ Ãâ°íµÇ°í ÀÖÀ¸¸ç, ¾Ë¶÷½ºÀ§Ä¡,
¾Ð·Â°è, Å©·¡ÆÛ, ¹è¼ö¹ëºê, ±âŸ ºÎ¼Ó ¹è°üÀç µîÀ¸·Î ±¸¼ºµÇ¾î ÀÖ½À´Ï´Ù.

The alarm valves of Shinyoung are optimized and essentially used for the sprinkler system. They detect the flow of water and alert a fire alarm when there is a fire. The alarm valves of Shinyoung are carefully examined by KFI(Korea Fire Institute) undertaking strict internal pressure tests, functional examinations and visual inspections. The alarm valve is consisted of an alarm switch, pressure gauges, a clapper, and other pipes.
 
     
   
     
 
 

¿ÀÀÛµ¿ÀÌ ¾ø½À´Ï´Ù.
2Â÷ ¹è°ü³»ÀÇ ÀÜ·ù°ø±â¿¡ ÀÇÇÑ °æº¸ÀÇ ¿ÀÀÛµ¿ÀÌ ¾ø½À´Ï´Ù.
No malfunction in alarm
No malfunction in the alarm caused by residual air in secondary pipes.

¿Àº¸¸¦ ¹æÁöÇÕ´Ï´Ù.
¹è°ü³»ÀÇ ´©¼öµîÀ¸·Î ¾Ë¶÷¹ëºê³»ÀÇ À¯·®ÀÌ 15§¤/minÀÌÇÏÀ϶§¿¡´Â ¹ëºê³»ºÎÀÇ º¼Ã¼Å© ¹ëºê°¡ ÀÏÁ¤¾Ð·ÂÀÇ ¹°À» ¹è°ü³»¿¡ °ø±ÞÇÏ¿© ¿Àº¸¸¦ ¹æÁöÇÕ´Ï´Ù.

¼³Ä¡°ø°£À» ÃÖ¼ÒÈ­ ÇÏ¿´½À´Ï´Ù.
Á¼Àº °ø°£¿¡¼­µµ ¼³Ä¡°¡ °¡´ÉÇϵµ·Ï ÄÞÆåÆ®ÇÏ°Ô ¼³°èÇÏ¿´½À´Ï´Ù.
Minimized installation space
Compactly designed alarm valves for small spaces.

¾ÈÀü¼ºÀ» ³ô¿´½À´Ï´Ù.
º»Ã¼°­µµ ½ÃÇèÀ» ÃÖ°í»ç¿ë¾Ð·ÂÀÇ 5¹è(70kgf/§²)·Î ¼³°èÇÏ¿© ¾ÈÀü¼ºÀ» ³ô¿´½À´Ï´Ù.
Improved the level of safety
Designed the body of valves to endure strength tests which five times more vicious than maximum usage pressure (70kgf/§²).
 
 
     
 
SYAV65
SYAV80
SYAV100
SYAV125
SYAV150
65A
80A
100A
125A
150A
2.1 MPa
1.4 MPa
KS B 1511 FF 10K
¼öÁ÷Çü
Ductile Iron, Brass, NBR
11 kg
13 kg
16 kg
29 kg
32 kg
 
 
   
 
ȣĪ ±Ô°Ý A B C D E G H I J ¾Ð·Â¼Õ½Ç µå·¡Àιëºê
65 A 87.5 240 87.5 230 120 77 180 32 25A 8.8kPa ¾Þ±Û TYPE
80 A 92.5 270 92.5 240 130 77 210 40 25A 9.2kPa
100 A 105 290 105 260 140 96 230 50 25A 10.1kPa
125 A 125 360 125 360 140 96 260 50 25A 12.0kPa
150 A 140 380 140 390 150 100 290 55 25A 11.1kPa
 
 
ȣĪ ±Ô°Ý A B C D E F G H I J ¾Ð·Â¼Õ½Ç µå·¡Àιëºê
65 A 87.5 250 87.5 330 160 25A 77 180 43 25A 8.8kPa U TYPE
80 A 92.5 270 92.5 340 165 25A 77 210 53 25A 9.2kPa
100 A 105 290 105 360 170 25A 96 230 62 25A 10.1kPa
125 A 125 360 125 360 170 25A 96 260 60 25A 12.0kPa
150 A 140 380 140 390 185 25A 100 290 65 25A 11.1kPa
 
     
   
 
 
¾Ë¶÷¹ëºêÀÇ 1,2Â÷Ãø¿¡ ¹°ÀÌ Â÷ÀÖ´Â
»óÅ¿¡¼­ È­Àç½Ã Ŭ·¡ÆÛ°¡ À¯¼öÀÇ È帧
¹æÇâÀ¸·Î ÀÛµ¿ÇÏ¸é ¾Ë¶÷½ºÀ§Ä¡ÀÇ Áö¿¬
ȸ·Î¿¡ ¼³Á¤µÈ ½Ã°£ÀÌ °æ°úµÈ ÈÄ Àü±âÀû
½ÅÈ£¸¦ È­Àç¼ö½Å¹ÝÀ¸·Î º¸³»¾î °æº¸¸¦
¿ï¸³´Ï´Ù.

In the state of the first and second sides of an alarm valve is filled with water, the clapper operates once fire occurs. The alarm switch sends signals to the fire alarm control panel once a setting time of delay circuit passes, and an alarm alert goes off.
 
     
   
 

No. Ç° ¸í ¼ö ·® ºñ °í
1 º»Ã¼ 1 ³»ºÎÆ÷Àå
2 ¾Ë¶÷½ºÀ§Ä¡ 1 º»Ã¼Á¶¸³
3 ¹è¼ö¹ëºê
(½ÎÀÌÆ®±Û¶ó½º³»Àå)
4 º»Ã¼Á¶¸³
4 ´Ï»Ü 3 º»Ã¼Á¶¸³
5 ´Ïµé¹ëºê 2 º»Ã¼Á¶¸³
6 ¾Ð·Â°è 2 ³»ºÎÆ÷Àå
 
     
 
¸ðµ¨¹øÈ£ A B C D E F G
SYAV-65 65 140 175 22 230 19 330
SYAV-80 80 150 185 22 240 19 360
SYAV-100 100 175 210 24 270 19 400
SYAV-125 125 210 250 24 280 23 440
SYAV-150 150 240 280 26 300 23 440
 
º» ü GC200
½ÃÆ®¸µ CAC406
º¼Ã¼Å© C3604BE
ÆÐÅ· N. B. R
 
 
 
 
     
   


¸ðµ¨¹øÈ£ SYAV 65~100
ȣĪ±Ô°Ý 1MPa - 65A ~ 150A
»ç¿ë¾Ð·Â¹üÀ§ 0.15 ~ 1.4 MPa
ÈÄ·»Áö±Ô°Ý KS B 1511 10k FF Flange
Àû¿ëÀ¯Ã¼ ¹°
Àç Áú ±¸ºÐ ¾Ë¶÷¹ëºê ¹öÅÍÇöóÀ̹ëºê
¸öü GCD450 ´ÚŸÀÏ
µð½ºÅ© SS400 STS304
½ÃÆ® NBR
 
ȣĪ ±Ô°Ý A B C D E G H I ¾Ð·Â¼Õ½Ç J
µå·¡ÀÎ
µå·¡Àιëºê
65 A 87.5 335 87.5 230 120 77 226 32 8.8kPa 25A ¾Þ±Û TYPE
80 A 92.5 350 92.5 240 130 77 256 40 9.2kPa 25A
100 A 105 370 105 260 140 96 282 50 10.1kPa 25A
125 A 125 432 125 360 140 96 316 50 12.0kPa 25A
150 A 140 460 140 390 150 100 346 55 11.1kPa 25A
 
 
ȣĪ ±Ô°Ý A B C D E F G H I ¾Ð·Â¼Õ½Ç J
µå·¡ÀÎ
µå·¡Àιëºê
65 A 87.5 335 87.5 330 160 25A 77 226 32 8.8kPa 25A U TYPE
80 A 92.5 350 92.5 340 165 25A 77 256 40 9.2kPa 25A
100 A 105 370 105 360 170 25A 96 282 50 10.1kPa 25A
125 A 125 432 125 360 170 25A 96 316 50 12.0kPa 25A
150 A 140 460 140 390 185 25A 100 346 55 11.1kPa 25A
 
     
     
 
  - ±×·çºê Á¶ÀÎÆ®¸¦ »ç¿ëÇÏ¿© À¯Áöº¸¼ö°¡ °£ÆíÇÏ´Ù.
  - Groove joints are used and it needs a minimum of
    maintenance.

  - ³»Áø¼ºÀÌ ¿ì¼öÇÏ´Ù.
  - Excellent for earth quake resistance.

  - ÇöÀå¿¡ µû¶ó µå·¡ÀιëºêÀÇ ÁÂ, ¿ì ¼±ÅÃÀÌ °¡´ÉÇÏ´Ù.
  - Able to select a drain for left and right depending
    on the circumstance.

  - GCD450À» »ç¿ëÇϹǷΠ³»±¸¼ºÀÌ ¿ì¼öÇÏ°í Ãë±ÞÀÌ
    ¿ëÀÌÇÏ´Ù.
  - Easy to use and high durability as the material of
    body is made of GCD450.
¸ðµ¨¹øÈ£ SYAVG 65~150
ȣĪ±Ô°Ý 1.0MPa(65A~150A) 1.6MPa(65A~150A)
»ç¿ë¾Ð·Â¹üÀ§ 0.15 ~ 1.4 MPa 0.15 ~ 2.2 MPa
ÈÄ·»Áö±Ô°Ý KS B 1507 ±×·çºê Á¶ÀÎÆ®
Àû¿ëÀ¯Ã¼ ¹°
Àç Áú ¸öü GCD450 ´ÚŸÀÏ
µð½ºÅ© SS400+NBR
½ÃÆ® STS304
¡Ø ´ÜÀÚ´ë ³»Àå
Çü½Ä½ÂÀιøÈ£ : °Ë17-8-2
                     °Ë20-6
 
     
   
 
ȣĪ ±Ô°Ý A B C D E F G H I ¾Ð·Â¼Õ½Ç J
µå·¡ÀÎ
µå·¡Àιëºê
65 A 74 224 79 300 160 25A 85 200 51 13.2kPa 25A U TYPE
80 A 86 240 79 305 165 25A 87 220 52 14.9kPa 25A
100 A 94 260 84 320 172 25A 97 240 63 12.3kPa 25A
125 A 94 310 96 340 176 25A 95 260 60 11.5kPa 25A
150 A 94 340 110 370 190 25A 100 290 65 8.8kPa 25A
 
     
     
 
  - ±×·çºê Á¶ÀÎÆ®¸¦ »ç¿ëÇÏ¿© À¯Áöº¸¼ö°¡ °£ÆíÇÏ´Ù.
  - Groove joints are used and it needs a minimum of
    maintenance.

  - ³»Áø¼ºÀÌ ¿ì¼öÇÏ´Ù.
  - Excellent for earth quake resistance.

  - ÇöÀå¿¡ µû¶ó µå·¡ÀιëºêÀÇ ÁÂ, ¿ì ¼±ÅÃÀÌ °¡´ÉÇÏ´Ù.
  - Able to select a drain for left and right depending
    on the circumstance.

  - GCD450À» »ç¿ëÇϹǷΠ³»±¸¼ºÀÌ ¿ì¼öÇÏ°í Ãë±ÞÀÌ
    ¿ëÀÌÇÏ´Ù.
  - Easy to use and high durability as the material of
    body is made of GCD450.
¸ðµ¨¹øÈ£ SYAVG 65~150
ȣĪ±Ô°Ý 1.0MPa(65A~150A) 1.6MPa(65A~150A)
»ç¿ë¾Ð·Â¹üÀ§ 0.15 ~ 1.4 MPa 0.15 ~ 2.2 MPa
ÈÄ·»Áö±Ô°Ý KS B 1507 ±×·çºê Á¶ÀÎÆ®
Àû¿ëÀ¯Ã¼ ¹°
Àç Áú ¸öü GCD450 ´ÚŸÀÏ
µð½ºÅ© SS400+NBR
½ÃÆ® STS304
¡Ø ´ÜÀÚ´ë ³»Àå
Çü½Ä½ÂÀιøÈ£ : °Ë17-8-2
                     °Ë20-6
 
     
   
 
ȣĪ ±Ô°Ý A B C D E F G H I ¾Ð·Â¼Õ½Ç J
µå·¡ÀÎ
µå·¡Àιëºê
65 A 74 360 79 300 160 25A 183 300 149 13.2kPa 25A U TYPE
80 A 86 360 79 310 165 25A 185 320 150 14.9kPa 25A
100 A 94 370 84 340 172 25A 213 356 179 12.3kPa 25A
125 A 109 410 96 380 176 25A 243 410 208 11.5kPa 25A
150 A 122 450 110 410 190 25A 248 440 213 8.8kPa 25A
 
     
 
  - ±×·çºê Á¶ÀÎÆ®¸¦ »ç¿ëÇÏ¿© À¯Áöº¸¼ö°¡ °£ÆíÇÏ´Ù.
  - Groove joints are used and it needs a minimum of
    maintenance.

  - ³»Áø¼ºÀÌ ¿ì¼öÇÏ´Ù.
  - Excellent for earth quake resistance.

  - GCD450À» »ç¿ëÇϹǷΠ³»±¸¼ºÀÌ ¿ì¼öÇÏ°í Ãë±ÞÀÌ
    ¿ëÀÌÇÏ´Ù.
  - Easy to use and high durability as the material of
    body is made of GCD450.

  - ¼ÒÄÏÀÌ°æƼ¸¦ Àû¿ëÇÏ¿© ½ÃÇè¹è°ü¿ëÀ¸·Î »ç¿ëÀÌ
    °£ÆíÇÏ´Ù.
¸ðµ¨¹øÈ£ SYAVG 65~150
ȣĪ±Ô°Ý 1.0MPa(65A~150A)
»ç¿ë¾Ð·Â¹üÀ§ 0.15 ~ 1.4 MPa
Á¢¼Ó±Ô°Ý KS B 1507 ±×·çºê Á¶ÀÎÆ®
Àû¿ëÀ¯Ã¼ ¹°
Àç Áú ¸öü GCD450 ´ÚŸÀÏ
µð½ºÅ© SS400+NBR
½ÃÆ® STS304
¡Ø ´ÜÀÚ´ë ³»Àå
Çü½Ä½ÂÀιøÈ£ : °Ë17-8-3
 
     
   
 
ȣĪ ±Ô°Ý A B C D E F G H I ¾Ð·Â¼Õ½Ç J
µå·¡ÀÎ
µå·¡Àιëºê
65 A 74 360 79 300 160 25A 183 428 149 13.2kPa 25A U TYPE
80 A 86 360 79 310 165 25A 185 468 150 14.9kPa 25A
100 A 94 370 84 340 172 25A 213 516 179 12.3kPa 25A
125 A 109 410 96 380 176 25A 243 610 208 11.5kPa 25A
150 A 122 450 110 410 190 25A 248 670 213 8.8kPa 25A
 
     
   
 
ȣĪ ±Ô°Ý L B D H
65 A 46 160 150 323
80 A 46 160 150 347
100 A 52 160 150 373
125 A 56 160 190 424
150 A 56 160 190 452
¡Ø ´ÜÀÚ´ë ³»Àå(¼±ÅÃ)
 
     
   
 
ȣĪ ±Ô°Ý ød øD øA B F L L
(¼¼ÆÃ)
H1 H2 E øM ¾Ð·Â¼Õ½Ç
65 A 65 76.3 72.3 16 8.7 98 98 69 174 160 150 9.1kPa
80 A 78 89.1 85.0 16 8.7 98 140 75 184 160 150 8.7kPa
100 A 100 114.3 110.0 16 8.7 116 146 93 198 160 150 8.1kPa
125 A 125 139.8 135.5 16 8.7 148 148 113 210 160 190 4.6kPa
150 A 150 165.2 160.8 16 8.7 148 148 126 224 160 190 5.6kPa
¡Ø ´ÜÀÚ´ë ³»Àå(¼±ÅÃ)