½Å¿µ°ø¾÷(ÁÖ)ÀÇ ÁغñÀÛµ¿½Ä ¹ëºê´Â °Ç½Ä ½ºÇÁ¸µÅ¬·¯ ½Ã½ºÅÛ¿¡ »ç¿ëµÇ´Â ¹ëºêÀÌ¸ç °³¹æÇüÀº 2Â÷Ãø ¹è°üÀÌ °Ç½ÄÀ¸·Î À¯ÁöµÇ¹Ç·Î,
Æó¼âÇü ¶Ç´Â °³¹æÇü ½ºÇÁ¸µÅ¬·¯ ¼³ºñ ¹× Æ÷¼ÒÈ­¼³ºñ µî¿¡ ´Ù¾çÇÏ°Ô »ç¿ëÇÒ ¼ö ÀÖÀ¸¸ç, 2Â÷Ãø ¹è°üÀº Æò»ó½Ã °¡¾Ð¼ö°¡ ¾ø´Â
°Ç½ÄÀÚµ¿¼ÒÈ­¿ë ¹ëºêÀÔ´Ï´Ù.
º»Ã¼¿¡ ºÎÂøµÈ Àüµ¿ º¼ ¹ëºê°¡ È­Àç°¨Áö±â¿¡ ÀÇÇØ ÀÛµ¿µÇ¸é ¼ÂÆÃÀ¯Áö µÇ¾îÀÖ´ø ÇÁ¸®¾×¼Ç¹ëºê°¡ °³¹æµÇ¸ç 2Â÷Ãø È­ÀçÁöÁ¡À¸·Î
¼ÒÈ­¼ö°¡ ¹æÃâµÇ¾î °³¹æµÈ Çìµå¸¦ ÅëÇÏ¿© È­À縦 Áø¾ÐÇÕ´Ï´Ù.

Deluge valves open to admit water through the main line when the pneumatic supply pressure is removed or the solenoid valve is activated.
Shingyoung Deluge valve is furnished fully factory-assembled and ready for installation at the appropriate point in the system.
 
     
   
     
 
 
¿ÀÀÛµ¿ÀÌ ¾ø½À´Ï´Ù.
´ÙÀ̾ÆÈÄ·½¹æ½ÄÀ¸·Î ¼ö°Ý ¹× ¾Ð·ÂÃæ°ÝÀ» Èí¼öÇÏ¿© ¿ÀÀÛµ¿¹æÁö ¹× ¹ÐÆó±â´ÉÀÌ ¶Ù¾î³³´Ï´Ù.
¿Àº¸¸¦ ¹æÁöÇÕ´Ï´Ù.
ÀüÀÚº¼ ¹ëºêÀÇ È­ÀçŽÁö¿¡ ÀÇÇÑ ÀÛµ¿ ¹× ºñ»ó½Ã ÀÎÀ§ÀûÀÎ ¼öµ¿°³¹æÀÌ °¡´ÉÇÑ ´Ù ±â´É¹ëºê·Î¼­, º»Ã¼°³¹æ ÀÛµ¿À» À§ÇÑ ¿îÀüºÎ¸¦ ÇÑ°÷À¸·Î Áý¾à½ÃÄÑ À¯Áö°ü¸®°¡ ¾ÆÁÖ Æí¸®ÇÕ´Ï´Ù.
¼³Ä¡°ø°£À» ÃÖ¼ÒÈ­ ÇÏ¿´½À´Ï´Ù.
ÀüÀÚ º¼ ¹ëºê ±âµ¿¿¡ ÀÇÇÑ ¹æÃâ¼ö´Â ¹è¼ö°üÀ¸·Î ¹è¼öµÇ¸ç, ¹è¼ö¹ëºê¿¡ ³»ÀåµÈ ÀÚµ¿¹è¼ö ÀåÄ¡´Â 2Â÷Ãø ÀÜ·ù¼ö¸¦ ¹è¼ö°üÀ¸·Î ¾ÈÀüÇÏ°Ô ¹èÃâ½ÃÅ°¹Ç·Î µ¿ÆÄÀÇ ¿°·Á°¡ ¾ø½À´Ï´Ù.
(ÀÌ°ÍÀº ¹ëºê½Ç ¹Ù´ÚÀÇ Ã»°áÀ¯Áö¸¦ º¸ÀåÇØÁÝ´Ï´Ù.)
¾ÈÀü¼ºÀ» ³ô¿´½À´Ï´Ù.
º»Ã¼°­µµ ½ÃÇèÀ» ÃÖ°í»ç¿ë¾Ð·ÂÀÇ 5¹è(70kgf/§²)·Î ¼³°èÇÏ¿© ¾ÈÀü¼º
À» ³ô¿´½À´Ï´Ù.

-Fast setting and easy restoration(patent of Shinyoung)
Resetting is simple when restoring operation
-It prevents misreport
The solenoid valve functions to detect fire and can be opened manually in emergency. Due to the simplicity of design of Shinyoung deluge valve, the safety controlling part is centralized, required maintenance is minimal.
-Minimized installation space
-Enhanced the level of safety
Designed the body of valves to endure strength tests which five times more vicious than maximum usage pressure(70kgf/§²)
 
SYPV-80~150
°Ë17-10-1(GCD450)
°Ë18-1(±×·çºêÇü), °Ë20-2
80A, 100A, 125A, 150A
20kgf/§² (2.0 MPa)
14kgf/§² (1.4 MPa)
KSB1511FF 10K
Á¾Çü(¼öÁ÷Çü)
DC24V/ÀÚµ¿.¼öµ¿°â¿ë
GCD450-23kg, 27kg, 33kg, 42kg
GCD450 : 25A
* GCD450Àº Áß·®ÀÌ °¡º­¿ì¸ç º¹±¸·¹¹ö°¡ ¾ø¾î ¼¼Æà ¹×
  ÀÛµ¿½ÃÇè ÈÄ Àç¼¼ÆÃÀÌ °£ÆíÇϸç, ¿ÀÀÛµ¿ÀÌ ¾ø½À´Ï´Ù.
The new model of GCD450 is light and has no restoration lever that it facilitates setting process and less false operations
 
 
     
   
 
  ÁغñÀÛµ¿½Ä ¹ëºêÀÇ ÀÛµ¿Àº È­Àç¹ß»ý½Ã
°¨Áö±âÀÇ ¿¬µ¿À¸·Î ÀüÀÚ º¼ ¹ëºê¸¦ °³¹æ
ÇÏ¿© ¹è¼ö°üÀ¸·Î ¹°ÀÌ ¹è¼öµÇ¸é ¹ëºê°¡
¿­¸®¸é¼­, 2Â÷Ãø ¾Ð·ÂS/WÀÇ ÀÛµ¿¿¡ ÀÇÇØ
È­Àç°æº¸°¡ ¹ß½ÅµÇ¸é¼­ 2Â÷Ãø È­ÀçÁöÁ¡ ¶Ç´Â ½ÃÇè¹æ¼ö±¸·Î ½Å¼ÓÇÏ°Ô ¼ÒÈ­¼ö°¡
¹æÃâµË´Ï´Ù.

Shinyoung deluge valve is a hydraulically operated valve, it requires a minimum line pressure of approximately 5 psig in order to function. The valve functions on a simple principle of pressure differential. The line pressure at the inlet of the valve is bypassed through the pilot control piping to the diaphragm chamber of the valve. The pressure works against the pressure under the valve seat. Because the effective area of the diaphragm is greater than that of the clapper, the valve is held tightly closed. As the solenoid valve allows the pressure to bleed off the diaphragm chamber, the two opposing pressures begin to balance and the valve will begin to open.

 
     
   
   
     
   
 
¸ðµ¨¹øÈ£
A
B
C
D
E
F
G
H
¾Ð·Â¼Õ½Ç
µå·¡ÀÎ
GCD450
GCD450
GCD450
GCD450
GCD450
SYPV-80
80
150
185
18
260
19
350
410
14.6kPa
25A
SYPV-100
100
175
210
18
280
19
410
420
11.2kPa
25A
SYPV-125
125
210
250
20
295
23
450
440
8.6kPa
25A
SYPV-150
150
240
280
22
330
23
470
470
8.0kPa
25A
º»Ã¼
GC200, GCD450
½ÃÆ®¸µ
CAC406
º¼Ã¼Å©
C3604BE
ÆÐÅ·
N.B.R
¿À¸®Çǽº
C3604BE
 
     
     
   
 
  - ±×·çºê Á¶ÀÎÆ®¸¦ »ç¿ëÇÏ¿© À¯Áöº¸¼ö°¡ °£ÆíÇÏ´Ù.
  - Groove joints are used and it needs a minimum of
    maintenance.

  - ³»Áø¼ºÀÌ ¿ì¼öÇÏ´Ù.
  - Excellent for earth quake resistance.

  - ÇöÀå¿¡ µû¶ó µå·¡ÀιëºêÀÇ ÁÂ, ¿ì ¼±ÅÃÀÌ °¡´ÉÇÏ´Ù.
  - Able to select a drain for left and right depending
    on the circumstance.

  - GCD450À» »ç¿ëÇϹǷΠ³»±¸¼ºÀÌ ¿ì¼öÇÏ°í Ãë±ÞÀÌ
    ¿ëÀÌÇÏ´Ù.
  - Easy to use and high durability as the material of
    body is made of GCD450.
¸ðµ¨¹øÈ£ SYPV80 SYPV100 SYPV125 SYPV150
ȣ Ī 80A 100A 125A 150A
½ÃÇè¾Ð·Â 2.1 MPa
ÃÖ°í»ç¿ë¾Ð·Â 1.4 MPa
ÈÄ·»Áö±Ô°Ý KS B 1507 ±×·çºê Á¶ÀÎÆ®
¼³Ä¡¹æÇâ ¼öÁ÷Çü
Àç Áú Ductile Iron, STS304, NBR
Áß ·® 18kg 21kg 23kg 31kg
 
     
 
ȣĪ ±Ô°Ý A B C D H E µå·¡ÀÎ ¾Ð·Â¼Õ½Ç µå·¡Àιëºê
80 A 130 200 130 290 260 25A 13.6kPa ¾Þ±Û
TYPE
100 A 145 200 147 293 280 25A 9.0kPa
125 A 152 220 155 295 290 25A 6.6kPa
150 A 167 220 176 304 320 25A 11.1kPa
 
     
     
   
 
  - ³»Áø¼ºÀÌ ¿ì¼öÇÏ´Ù.
  - Excellent for earth quake resistance.

  - ÇöÀå¿¡ µû¶ó µå·¡ÀιëºêÀÇ ÁÂ, ¿ì ¼±ÅÃÀÌ °¡´ÉÇÏ´Ù.
  - Able to select a drain for left and right depending
    on the circumstance.

  - GCD450À» »ç¿ëÇϹǷΠ³»±¸¼ºÀÌ ¿ì¼öÇÏ°í Ãë±ÞÀÌ
    ¿ëÀÌÇÏ´Ù.
  - Easy to use and high durability as the material of
    body is made of GCD450.

  - ³»ºÎ ¾Ð·Â¼Õ½ÇÀÌ ÃÖ¼ÒÈ­ÇÏ¿© À¯Ã¼ È帧ÀÌ ¿øÈ°ÇÏ´Ù.
  - Minimized internal pressure loss enbles the flow
    of water.
ȣ Ī 80A 100A 125A 150A
ȣĪ±Ô°Ý 1.0 MPa
»ç¿ë¾Ð·Â¹üÀ§ 0.15 ~ 1.4 MPa
ÈÄ·»Áö±Ô°Ý KS B 1507 ±×·çºê Á¶ÀÎÆ®
Àû¿ëÀ¯Ã¼ ¹°
Àç Áú ±¸ ºÐ ÇÁ¸®¾×¼Ç¹ëºê ¹öÅÍÇöóÀ̹ëºê
¸ö ü GCD450 ´ÚŸÀÏ
µð½ºÅ© GCD450
½Ã Æ® NBR
Áß ·® 34kg 40kg 50kg 60kg
¡Ø ´ÜÀÚ´ë ³»Àå
Çü½Ä½ÂÀιøÈ£ : °Ë18-1
 
     
 
ȣĪ ±Ô°Ý A B C D E H J µå·¡ÀÎ ¾Ð·Â¼Õ½Ç µå·¡Àιëºê
80 A 290 550 130 250 450 498 25A 13.6kPa ¾Þ±Û
TYPE
100 A 293 580 147 260 460 542 25A 9.0kPa
125 A 295 610 155 280 500 586 25A 6.6kPa
150 A 304 630 176 300 520 626 25A 11.1kPa
 
     
     
   
 
  - ƯÇã Ãâ¿øÇÏ¿© Ãâ½Ã
  - Á¶¸³ÀΰǺñ ¹× ÀÚÀç¿ø°¡ Àý°¨
  - ¹è°üÀÛ¾÷ÀÌ ÇÊ¿ä¾ø¾î ÀÛ¾÷¼º ´ÜÃà
  - 3¹æ º¼¹ëºê »ç¿ëÇϸç üũ¹ëºê·Î Áø°øÂ÷´Ü È¿°ú
  - ½ÃÆ®¸µ¿¡ Å©·¹ÆÛ ¾ÈÂøÀÌ ¿ëÀÌ
  - ·¹¹ö¾øÀÌ ÀÚµ¿ º¹±Í
  - ´ÜÀÚÀç(¼¾¼­±â´É) ±³Ã¼ ¿ëÀÌ
  - ³ªºñº¼¹ëºê »ç¿ëÀ¸·Î ÀûÀº °ø°£¿¡µµ ¿À¸®Çǽº ¼ö¸®°¡ ¿ëÀÌ
  - ³»Áø¼ºÀÌ ¿ì¼öÇÏ´Ù.
  - Excellent for earth quake resistance.
  - ÇöÀå¿¡ µû¶ó µå·¡ÀιëºêÀÇ ÁÂ, ¿ì ¼±ÅÃÀÌ °¡´ÉÇÏ´Ù.
  - Able to select a drain for left and right depending
    on the circumstance.
  - GCD450À» »ç¿ëÇϹǷΠ³»±¸¼ºÀÌ ¿ì¼öÇÏ°í Ãë±ÞÀÌ ¿ëÀÌ
  - Easy to use and high durability as the material of
    body is made of GCD450.
  - ³»ºÎ ¾Ð·Â¼Õ½ÇÀÌ ÃÖ¼ÒÈ­ÇÏ¿© À¯Ã¼ È帧ÀÌ ¿øÈ°ÇÏ´Ù.
  - Minimized internal pressure loss enbles the flow
    of water.
ȣ Ī 100A ~ 150A
ȣĪ±Ô°Ý 1.6 MPa(100A, 150A)
»ç¿ë¾Ð·Â¹üÀ§ 0.15 ~ 2.2 MPa
ÈÄ·»Áö±Ô°Ý KS B 1507 ±×·çºê Á¶ÀÎÆ®
Àû¿ëÀ¯Ã¼ ¹°
Àç Áú ±¸ ºÐ ÇÁ¸®¾×¼Ç¹ëºê ¹öÅÍÇöóÀ̹ëºê
¸ö ü GCD450 ´ÚŸÀÏ
µð½ºÅ© GCD450+NBR
½Ã Æ® STS304
Áß ·® 40kg ~ 60kg
¡Ø ´ÜÀÚ´ë ³»Àå
Çü½Ä½ÂÀιøÈ£ : °Ë21-9

  - ¡ØGCD450Àº Áß·®ÀÌ °¡º­¿ì¸ç, º¹±¸·¹¹ö°¡ ¾ø¾î
    ¼¼Æà ¹× ÀÛµ¿½ÃÇè ÈÄ Àç¼¼ÆÃÀÌ °£ÆíÇϸç,
    ¿ÀÀÛµ¿ÀÌ ¾ø½À´Ï´Ù.
 
     
 
ȣĪ ±Ô°Ý A B C D E H J µå·¡ÀÎ ¾Ð·Â¼Õ½Ç µå·¡Àιëºê
100 A 293 580 147 260 460 542 25A - ¾Þ±Û
TYPE
150 A 304 630 176 300 520 626 25A 18.0kPa